Pit+Plus Installation Guide Patent Pending
Before Getting Started Read and follow safety instructions. Refer to product data plate(s) for additional operating instructions and specifications. s WARNING This is the safety alert symbol. When you see this ! symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury: s WARNING DANGER ! warns about hazards that will cause serious personal injury, death or major property damage if ignored.
Table of Contents Before Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Start Up Procedure . . . . . . . . . . . . . .
Pit+Plus Premium Simplex Package Systems TM Features 1 2 5 3 4 7 6 8 Finish Cover (1) - A finish cover is provided with each basin to help protect the basin top from construction debris during installation. After basin installation, the cover can be removed for cleaning then reinstalled for a clean and finished look. Finish Flange Bolts (2) – Two flange bolts are provided to secure the finish cover.
Pit+Plus Premium Simplex Package Systems TM Start Up Procedure Step 1 Remove finish cover and set aside. Step 2 Remove bolts and washers from pump access cover and set cover aside. Step 3 Observe position of pump. The pump should be upright with standoff feet located within the three (3) integral torque stops (Figure 1). Figure 1 Step 4 Verify that the pump discharge pipe is securely connected to the exit pipe (inside the basin) with the flexible coupling.
Pit+Plus Premium Simplex Package Systems TM Step 6 External Level Control Option - If the basin is equipped with an External Control Module (ECM™), verify that the sensor tube extending from bottom of control module (Figure 3) is not damaged. Figure 3 Note: The cord/plug for the ECM™ (Figure 3) must be unobstructed at the plug end, to allow for air to pass through the vent tube. Step 7 Remove temporary pipe caps from the vent and discharge pipes.
Pit+Plus Premium Simplex Package Systems TM Pit+Plus Troubleshooting Guide Condition Possible Cause Circuit breaker tripped or power turned off Corrective Action Reset circuit breaker or correct electrical supply 1. Disconnect electrical power Pump will not operate 2. Remove piggyback plug from outlet Switch failure 3. Plug pump power cable into outlet 4. Turn on electrical power 5.
Pit+Plus Premium Simplex Package Systems TM ECM Troubleshooting Guide Condition Pump does not shut off. NOTE: Before troubleshooting automatic control, check to see that pump operates on manual control. To do this, disconnect electrical power, remove piggyback plug from the outlet, plug pump power cable into outlet, turn on electrical power, if pump operates the switch is in failure mode. Pump runs but does not discharge liquid Pump does not deliver rated capacity.
Pit+Plus Premium Simplex Package Systems TM Replacement Parts Replacement Parts (Pit+Plus Jr. with ECM) Replacement Parts (Pit+Plus Jr. with Floats) Replacement Parts (Pit+Plus Sr. with ECM) Replacement Parts (Pit+Plus Sr.
Pit+Plus Premium Simplex Package Systems TM Replacement Parts (Pit+Plus Jr. with ECM) REPLACEMENT PARTS ITEM NO. 1 2 PART NO. 113221101 113221102 113221103 113221104 113268 DESCRIPTION QTY. Basin 2V2D Basin 3V3D Basin 2V3D Basin 3V2D Finish Cover 1 1 1 1 1 3 113269 Finish Cover Wing Bolt 2 4 5 6 7 8 9 113250 113251 113277 113253 113259 113266 113562 113564 Pump Access Cover Pump Access Cover Gasket ECM Assembly Controls Cover Gasket Pressure Pole Jr.
Pit+Plus Premium Simplex Package Systems TM Replacement Parts (Pit+Plus Jr. with Floats) REPLACEMENT PARTS ITEM NO. 1 2 PART NO.
Pit+Plus Premium Simplex Package Systems TM Replacement Parts (Pit+Plus Sr. with ECM) REPLACEMENT PARTS ITEM NO. 1 2 PART NO. 113221101 113221102 113221103 113221104 113268 DESCRIPTION QTY. Basin 2V2D Basin 3V3D Basin 2V3D Basin 3V2D Finish Cover 1 1 1 1 1 3 113269 Finish Cover Wing Bolt 2 4 5 6 7 8 9 113250 113251 113277 113253 113259 113266 113562 113564 Pump Access Cover Pump Access Cover Gasket ECM Assembly Controls Cover Gasket Pressure Pole Jr.
Pit+Plus Premium Simplex Package Systems TM Replacement Parts (Pit+Plus Sr. with Floats) REPLACEMENT PARTS ITEM NO. 1 2 PART NO.
Pit+Plus Premium Simplex Package Systems TM Replacement Parts (ECM) REPLACEMENT PARTS ITEM NO. 1 14 PART NO. 113264 DESCRIPTION ECM Housing QTY.
Pit+Plus Premium Simplex Package Systems TM Maintenance Pump Removal and Installation Step 1 Disconnect pump and switch from power supply Step 2 Remove pump access cover and set aside Step 3 Remove cord grommet from the switch access cover then separate the pump power cord from the grommet. Step 4 Loosen the two (2) band clamps on the flexible coupling connecting the pump discharge pipe to the basin discharge pipe.
Pit+Plus Premium Simplex Package Systems TM Step 4 Remove the six (6) bolts securing the switch module to the basin and remove. Feed pump cord through the cord grommet opening until the switch module is free. Step 5 Remove float switch by loosening the plastic wing nut opposite the cord grip. Loosen the wing nut until the cord can be removed from the cord grip. Note: It is not necessary to remove the wing nut completely to remove float cord. Step 6 Install new float switch.
LIMITED WARRANTY THIS WARRANTY SETS FORTH THE COMPANY’S SOLE OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT. Franklin Electric Company, Inc. and its subsidiaries (hereafter “the Company”) warrants that the products accompanied by this warranty are free from defects in materials or workmanship of the Company that exist at the time of sale by the Company and which occur or exist within the applicable warranty period.
The Company reserves the right at any time, and from time to time, to make changes in the design and/or improvements upon its product without thereby imposing any obligation upon itself to make corresponding changes or improvements in or upon its products already manufactured and/or previously sold. The Company further reserves the right to substitute parts or components of substantially equal quality in any warranty service required by operation of this Limited Warranty.
NOTES: 19
For technical assistance, please contact . . . . . . . . . . . . . . . . . 800.701.7894 Pour l’aide technique, entrez s’il vous plaît en contact . . . . . . 800.701.7894 Para la ayuda técnica, por favor póngase en contacto . . . . . . 800.701.7894 www.littlegiant.com lgnet@fele.com Form 998749 Rev. 0 03.15 Franklin Electric Co., Inc. Oklahoma City, OK 73157-2010 Phone: 1.800.701.7894 Fax: 1.405.228.