User Guide

INTRODUCTION
Little Giant Submersible High Temperature 10E Series Effluent
Pumps are recommended for use in basins or lift stations and
suitable for pumping effluent wastewater and other non-explosive,
non-corrosive liquids. The 10E Series Effluent Pumps have 3/4"
spherical solids handling capability.
Continuous automatic operation can be achieved with the use of
the Integral Float Switch.
UNPACKING
Little Giant pumps are carefully packaged, inspected and tested
to ensure safe operation and delivery. When you receive your pump,
examine it carefully to determine that there are no broken or damaged
parts that may occurred during shipment. If damage has occurred,
make notation and notify the firm from which you purchased the
pump and they will assist you in replacement or repair, if required.
SPECIFICATIONS
Discharge: 10E Series — 1-1/2" NPT Vertical
Intake: 10E Series — 3/4" screened opening
Housing: Motor: Cast iron
Relay: Cast iron
Volute: Cast iron
Screen: 10E Series — Nylon
Impeller: Vortex design corrosion-proof nylon, with pressure
relief vanes
Motor: Split phase induction, 1750 RPM, with automatic
reset thermal overload protection
Hardware: 300 series stainless steel
Dual Bearings: Double shielded ball
Gaskets/Seals: Neoprene, Nitrile for high temperature
Shaft Seal: Mechanical, spring-loaded, stationary carbon with
Viton boot and rotating Ni Resist seat
Power Cord: 16 AWG 3-conductor copper stranded type
SJOW-A/SJOW
Cooling: The motor housing contains a cooling oil to
provide cooling for the motor and to lubricate
bearings and seals. These pumps are capable of
operating with the motor housing partially exposed
for extended periods of time, providing sufficient
motor cooling and bearing lubrication; however,
for the best cooling and longest motor life, the
liquid level being pumped should normally be
above the top of the cast iron motor housing.
SAFETY GUIDELINES
WARNING: RISK OF ELECTRIC SHOCK. THIS PUMP IS
SUPPLIED WITH A GROUNDING CONDUCTOR AND/OR
GROUNDING-TYPE ATTACHMENT PLUG. TO REDUCE THE RISK
OF ELECTRICAL SHOCK, BE CERTAIN THAT IT IS CONNECTED
TO A PROPERLY GROUNDED GROUNDING-TYPE RECEPTACLE.
Your 115V pump is equipped with a 3-prong electrical plug. The
third prong is to ground the pump to prevent possible electrical shock
hazard. Do not remove the third prong from the plug. A separate
branch circuit is recommended. Do not use an extension cord.
When a pump is in a basin, etc., do not touch motor, pipes or water
until unit is unplugged or shut off. If your installation has water or
moisture present, do not touch wet area until all power has been
turned off. If shut-off box is not accessible, call the electric company
to shut off service to the house, or call your local fire department
for instructions. Failure to follow this warning can result in fatal
electrical shock.
1
HT-10E-CIM
HT-10E-CIA-FS
NON-MERCURY
SUBMERSIBLE
HIGH-TEMPERATURE
EFFLUENT PUMPS
MODEL
NO.
CATALOG
NO. HP VOLTS
SOLIDS
SIZE
(dia. in.)
AMPS/
WATTS
PERFORMANCE (GPM @ HEAD
PWR CRD
(ft.)
WEIGHT
(lbs.)
DIMENSIONS
(HxLxW in.)
WATER
TEMP. 5' 10' 15' 20' (ft.) P.S.I.
HT-10E-CIM 511600 1/2 115 3/4 10/900
73°F
200°F
80
75
70
67
59
52
37
22
24
22
10.4
9.5
15 38 10.25x9.6x9.12
HT-10E-CIA-FS 511700 1/2 115 3/4 10/900
73°F
200°F
80
75
70
67
59
52
37
22
24
22
10.4
9.5
15 39 10.25x9.6x9.12
Figure 1.
All models are 60 Hz.
Little Giant
P. O. Box 12010
Oklahoma City, OK 73157-2010
405.947.2511 • Fax: 405.947.8720
www.LittleGiantPump.com