WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
MOUNTING THE FIXTURE
Installation (see fig.1)
1. Shut off the power at the circuit breaker and remove old fixture,
including the crossbar.
2. Thread the pipe screw part way into the center hole of the single
bar and secure with hex nut.
3. Attach the single bar to the junction box using two box screws.
The side of the single bar marked “GND” must face out.
4. Follow wiring instructions carefully (see fig.2)
5.
Place the lamp back plate over the nipple then tighten it with the
ball nut (C).
6. Put glass shade (A) into the hook (B) carefully.
7. Install the light bulb in accordance with the fixture’s
specifications. DO NOT EXCEED THE MAXIMUM
WATTAGE RATING!
Wiring (see fig.2)
1. Connect the electrical wires as follows. Connect the
black wire from the fixture to the black house (hot)
Wire. Connect the white wire from the fixture to the
white (neutral) house wire. Make sure all wire nuts are
secured. You may wrap the connections with electrical
tape.If your outlet box has a ground wire (green or bare
copper) connect fixture’s ground wire to it. Otherwise
attach the bare copper fixture wire to the green ground
screw on the single bar.
2.Tuck the wire connections neatly into the wall junction
box.
Fig.1
Fig.2
White or
HOUSE
Black
WIRES
(Hot)
Smooth
FIXTURE
WIRES
Black or
Ribbed
WIRES
FIXTURE
Bare Copper(Ground)
FIXTURE
WIRES
Copper
(Ground)
HOUSE
(Neutral)
WIRES
White
Bare
Green or
WIRES
HOUSE
A
B
C