User's Manual

26 Revision 2 GM550 v1043 FCC-IC.doc
Lockout Triggers
Different events can be programmed to cut voltage on the lockout wires of the yellow cable.
Each lockout wire can be linked to a different combination of lockout conditions.
Step 1. Press Menu Next Next Next Enter Next Next Next Next
Next Next Enter Next Next Next to access menu 4G4) White
wire lockout trigger.
Step 2. Select which alarm conditions will trigger lockout on the white wire.
Step 3. Add the lockout codes for the selected alarms together to find the lockout trigger
number.
Step 4. Use Up and Down to adjust the white wire lockout trigger number.
Step 5. Press Next to advance to the next wire trigger menu page and repeat steps 2
through 5, or, press Exit three times to return to the operation display.
Condition
Code
Maximum wind speed 1
Minimum angle 2
Maximum angle 4
Overload 8
Minimum sum load 16
Maximum radius 32
Maximum length 64
Two-block 128
Maximum wind gust 256
Maximum rope payout 512
Minimum slew 1024
Maximum slew 2048
Maximum tip height 4096
Maximum imbalance factor 8192
Minimum slack rope 16384
Table: Lockout codes
Two-Block 128
Maximum length 64
Overload 8
Maximum angle 4
Maximum wind speed + 1
Example: Typical white wire lockout trigger; two-
block, maximum boom length, overload, high angle
and maximum wind speed
White wire lockout trigger = 205
Maximum radius 32
Minimum angle + 2
Example: Typical green wire lockout trigger;
maximum load radius and minimum boom angle
Green wire lockout trigger = 34