Angle Calibration Procedure 2: Correct with the GS550
Calibrate angle indication by adjusting the trim (offset) value in the GS550 display; the GS550 will
then communicate the updated trim value to the sensor.
Step 1. Position the boom at a precisely known angle.
Step 2. Press Menu Next Next Next Enter Next Enter Next Enter
to go to manual calibration menu page 4B2A)
Step 3. Use Back and Next to select the angle sensor to be calibrated.
Step 4. Press Enter Next to got to the trim adjustment page.
Step 5. Use Up and Down to adjust the trim value.
Example:
If angle indicated is 0.3° over the actual angle, adjust the trim value to -0.3.
Example:
If angle indicated is 0.9° below the actual angle, adjust the trim value to 0.9.
Step 6. Press Enter to save changes.
Step 7. Press Exit four times to return to the operation display.
Step 8. Verify accurate angle indication at both very high and very low angles.