Operation Manual
29
REFRESHING THE OIL
1. Place the generator on a level surface and warm up the engine for several
minutes Then stop the engine.
2. Remove the oil filler cap.
3. Place the oil collect can under the motor, unscrew the oil drain plug and drain
the oil completely.
4. Replace the oil drain plug.
5. Fill with fresh oil up to the maximum level.
6. Replace the oil filler cap.
Caution: be sure no foreign material enters the crankcase.
8. APPLICATION RANGE
AC application
Model 75029 Power
factor
50 Hz
230 V
2300 W
1
50 Hz
230 V
1800 W
0,7~0,8
50 Hz
230 V
1600 - 2200 W
0,7~0,95
AC output
Unit 75029
Rated voltage V 230 V AC
Frequency Hz 50
AC current A 9,1
Rated output VA 2000
Max. output VA 2400