Standard Features
81% Thermal Efficiency
Electronic Temperature Control
Fan Assisted Combustion
Sealed Combustion Chamber
Stainless Steel Burners
Low NOx Operation Exceeds the most
Stringent Air Quality Requirements
ASME Copper Finned Tube
Heat Exchanger
160 psi Working Pressure
Gasketless Heat Exchanger Design
Pump Relay w/ Delay
Down Stream Test Valve
Referenced Gas Valves
Loch-Heat Ceramic Tile
Combustion Chamber
Hot Surface Ignition
Adjustable High Limit w/ Manual Reset
ASME Pressure Relief Valve
Temperature & Pressure Gauge
Flow Switch
24 Volt Control System
BMS Terminal Strip
Combustion Air Filter
Freeze Protection
10 Year Limited Warranty on Heat
Exchanger (See warranty for details)
Optional Equipment
Alarm Bell
Contacts on any Failure
Contacts for Air Louvers
Cupro-Nickel Heat Exchanger
High & Low Gas Pressure Switch
w/ Manual Reset
Outdoor Reset Control
Manual Reset Low Water Cut-Off
w/ test
Stack Frame
MP
2
Sequencer
Available Firing Systems
M9 Hot Surface Ignition with
Electronic Supervision (Standard)
M13 GE GAP/FM/CSD1
M7 California Code
Venting
Outdoor Vent Cap
Registered under U.S. Patent # 5,989,020
For Ease In Ordering
By Model Number
CB N 0497 M9
MODEL
Btu/hr INPUT
This boiler is a 495,000 Btu/hr,
natural gas Copper-Fin.
It has M9 firing controls
NAT. GAS
FIRING
CONTROLS
Copper-Fin Heating Boiler Dimensions & Spec i fi ca tions
Input Heating Net
Model Max Thermal Capacity I=B=R Gas Vent Shipping
Number MBH Efficiency MBH MBH A B C D E F G Conn. Size Weight
CBN0497 495 81% 401 349 31-1/2” 45-1/4” 22-1/4” 12-1/2” 9-1/2” 22-3/4” 29-1/2” 1-1/4” 6” 440
CBN0647 645 81% 522 454 31-1/2” 56-3/4” 22-1/4” 12-1/2” 9-1/2” 28-1/2” 29-1/2” 1-1/4” 8” 510
CBN0747 745 81% 603 524 31-1/2” 64” 22-1/4” 12-1/2” 9-1/2” 32” 29-1/2” 1-1/4” 8” 550
CBN0987 985 81% 798 694 36” 48-1/4” 33-1/2” 15-3/4” 8-1/2” 8-1/2” 33-3/4” 2” 10” 845
CBN1257 1255 81% 1,017 884 36” 58-1/2” 33-1/2” 15-3/4” 9-1/2” 10-1/2” 33-3/4” 2” 12” 905
CBN1437 1435 81% 1,162 1,010 36” 68-3/4” 33-1/2” 15-3/4” 10-1/2” 10-1/2” 33-3/4” 2” 12” 1050
CBN1797 1795 81% 1,454 1,264 36” 82-1/4” 33-1/2” 15-3/4” 11” 11” 33-3/4” 2” 14” 1193
CBN2067 2065 81% 1,673 1,455 36” 92-1/2” 33-1/2” 15-3/4” 11” 11” 33-3/4” 2” 14” 1350
Notes: Change ‘N’ to ‘L’ for LP gas models. Water connections for models CB 0497-747 are 2” NPT on 6-1/2” centers.
No deration on LP models. Water connections for models CB 0987-2067 are 2-1/2” NPT on 11-1/4” centers.
Performance data based on manufacturer test results.