2 Owner manual

Installation & Operation Manual
2 General venting (continued)
13
Figure 2-6_E-Rite Sidewall Venting - See page 27
for more details
Figure 2-7_Outdoor Venting - See page 14 for
more details
This pool heater has six (6) venting options. They are: (1)
Conventional Negative Draft Venting with vertical rooftop flue
termination and combustion air supplied from the equipment
room, (2) DirectAire Vertical Venting with a vertical
conventional vent for flue products and a combustion air pipe
from either the sidewall or rooftop, (3) Power Sidewall Venting
to exhaust flue products out a sidewall with a powered vent
assembly and combustion air supplied from the equipment
room (4) DirectAire Horizontal Venting with a powered vent
assembly to exhaust the flue products out a sidewall and a
combustion air pipe from the sidewall, (5) E-Rite Sidewall
Venting which uses the internal combustion air fan to exhaust
the flue products out a sidewall vent termination with a limited
vent length. Combustion air for an E-Rite Sidewall vent must be
supplied with a combustion air pipe from the sidewall,
(6) Outdoor Venting using the factory supplied vent cap
installed on the unit. All pool heaters are shipped from the
factory equipped for Outdoor Installation. All other optional
vent systems require the removal of the outdoor vent cap and
installation of specific vent kits and venting materials. The
following is a detailed explanation of the installation
requirements for each venting system, components used and
part numbers of vent kits for each model.
Figure 2-5_Power DirectAire Horizontal Venting - See
page 25 for more details