Installation Instructions
SECTION 2.24
2.2 Wiring Diagram
Electromagnetic
Lock A
V+
V-
NO
COM
NC
Electromagnetic
Lock B
V+
V-
NO
COM
NC
Access Control Power Supply
1
NO OR NC
AC100-240
2 3
1 2 3 4 5 6 7 8
Access Control
Wireless Transceiver
+12V
GND
PUSH GND
PUSH 12V
LOCK NC
Exit Button
BUTTON-SW
Data 0
Data 1
GND 1
GND1
Wiegand 26
Lockly Wireless Exit
Button do not require
cable connection.
PUSH
NC
On Wireless Installation,
PUSH and NC cables
should connect to PUSH
GND and LOCK NC on
the wireless transceiver
terminals.
Note:
The NC port is used to detect the
opening and closing status of the door.
Only the Lockly Guard Electromagnetic
Lock supports this function. If you use a
third-party Electromagnetic Lock other
than the Lockly Guard Electromagnetic
Lock, you do not need to connect this
NC cable.