SDS

IDH number: 1602122
Product name: Loctite PL Landscape Block Adhesive
Page 4 of 8
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Employers should complete an assessment of all workplaces to determine the need for, and selection of, proper exposure
controls and protective equipment for each task performed.
Hazardous Component(s)
ACGIH TLV
OSHA PEL
AIHA WEEL
OTHER
Limestone
10 mg/m3 TWA Total
dust.
5 mg/m3 PEL
Respirable fraction.
15 mg/m3 PEL Total
dust.
None
None
Acetone
250 ppm TWA
500 ppm STEL
1,000 ppm (2,400
mg/m3) PEL
None
None
Kaolin
2 mg/m3 TWA
Respirable fraction.
5 mg/m3 PEL
Respirable fraction.
15 mg/m3 PEL Total
dust.
15 MPPCF TWA
Respirable fraction.
50 MPPCF TWA
Total dust.
5 mg/m3 TWA
Respirable fraction.
15 mg/m3 TWA Total
dust.
None
None
Petroleum resins
None
None
None
None
Rosin ester
None
None
None
None
Methyl acetate
200 ppm TWA
250 ppm STEL
200 ppm (610
mg/m3) PEL
None
None
Titanium dioxide
10 mg/m3 TWA
15 mg/m3 PEL Total
dust.
15 MPPCF TWA
Respirable fraction.
15 mg/m3 TWA Total
dust.
50 MPPCF TWA
Total dust.
5 mg/m3 TWA
Respirable fraction.
None
None
Quartz (SiO2), <1% respirable
0.025 mg/m3 TWA
Respirable fraction.
2.4 MPPCF TWA
Respirable.
0.1 mg/m3 TWA
Respirable.
0.05 mg/m3 TWA
(Respirable dust.)
(Respirable dust.)
0.025 mg/m3
OSHA_ACT
(Respirable dust.)
0.05 mg/m3 PEL
Respirable dust.
None
None
Engineering controls:
Local exhaust ventilation is recommended when general ventilation is not
sufficient to control airborne contamination below occupational exposure
limits.
Respiratory protection:
Use a NIOSH approved air-purifying respirator if the potential to exceed
established exposure limits exists. When workplace hazards warrant the use
of a respirator, appropriate respirators must be used, and a program that
follows 29 CFR 1910.134 must be followed.
Eye/face protection:
Safety goggles or safety glasses with side shields.
Skin protection:
Chemical resistant, impermeable gloves.