SDS

IDH number: 1618149
Product name: Loctite® PL® Polyurethane Self Leveling Concrete Sealant
Page 3 of 7
Hazardous combustion products:
Nitrous gases Irritating fumes. Isocyanate vapors.
6. ACCIDENTAL RELEASE MEASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected
personnel.
Environmental precautions:
Ventilated area. Wear appropriate protective equipment and clothing during
clean-up. Prevent further leakage or spillage if safe to do so. Do not allow
product to enter sewer or waterways.
Clean-up methods:
Scrape up spilled material and place in a closed container for disposal.
Dispose of according to Federal, State and local governmental regulations.
7. HANDLING AND STORAGE
Handling:
Avoid contact with eyes, skin and clothing. Avoid extreme temperatures. Wash
thoroughly after handling. Protect from moisture. Use only with adequate
ventilation.
Storage:
For safe storage, store between 18.3 °C (64.9 °F) and 40 °C (104°F)
Avoid moisture. Keep in a cool, well ventilated area away from heat, sparks
and open flame. Keep container tightly closed until ready for use.
For information on product shelf life, please review labels on container or check the Technical Data Sheet.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Employers should complete an assessment of all workplaces to determine the need for, and selection of, proper exposure
controls and protective equipment for each task performed.
Hazardous Component(s)
ACGIH TLV
OSHA PEL
AIHA WEEL
OTHER
Limestone
10 mg/m3 TWA Total
dust.
5 mg/m3 PEL
Respirable fraction.
15 mg/m3 PEL Total
dust.
None
None
Bis(2-propylheptyl) phthalate
None
None
None
None
Stoddard solvent, <0.1% Benzene
100 ppm TWA
500 ppm (2,900
mg/m3) PEL
None
None
Talc
2 mg/m3 TWA
Respirable fraction.
20 MPPCF TWA
2.4 MPPCF TWA
Respirable.
0.1 mg/m3 TWA
Respirable.
0.3 mg/m3 TWA Total
dust.
None
50 ppm
Calcium oxide
2 mg/m3 TWA
5 mg/m3 PEL
None
None
Toluene-2,4-diisocyanate
0.005 ppm TWA
0.02 ppm STEL
(Sensitizer.)
0.02 ppm (0.14
mg/m3) Ceiling
None
None
Benzenepropanoic acid, 3,5-bis(1,1-
dimethylethyl)-4-hydroxy-, C7-9-branched
alkyl esters
None
None
None
None
Titanium dioxide
10 mg/m3 TWA
15 mg/m3 PEL Total
dust.
None
None
Toluene-2,6-diisocyanate
0.005 ppm TWA
0.02 ppm STEL
(Sensitizer.)
None
None
None
Engineering controls:
Local exhaust ventilation is recommended when general ventilation is not
sufficient to control airborne contamination below occupational exposure
limits.