Specification
IDH number: 2066118
Product name: Loctite Super Glue Precision Pen
Page 3 of 6
Hazardous combustion products:
Trace amounts of toxic and/or irritating fumes may be released and the use of
breathing apparatus is recommended.
6. ACCIDENTAL RELEASE MEASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected
personnel.
Environmental precautions:
Do not allow product to enter sewer or waterways.
Clean-up methods:
Do not use cloths for mopping up. Flood with water to complete
polymerization and scrape off the floor. Cured material can be disposed of as
non-hazardous waste.
7. HANDLING AND STORAGE
Handling:
Avoid contact with eyes, skin and clothing. Avoid breathing vapors or mists of
this product. Wash thoroughly after handling. Avoid contact with fabric or
paper goods. Contact with these materials may cause rapid polymerization
which can generate smoke and strong irritating vapors, and cause thermal
burns.
Storage:
Keep in a cool, well ventilated area away from heat, sparks and open flame.
Keep container tightly closed until ready for use.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Employers should complete an assessment of all workplaces to determine the need for, and selection of, proper exposure
controls and protective equipment for each task performed.
Hazardous Component(s)
ACGIH TLV
OSHA PEL
AIHA WEEL
OTHER
Ethyl 2-cyanoacrylate
0.2 ppm TWA
None
None
None
Treated fumed silica
10 mg/m3 TWA
Inhalable dust.
3 mg/m3 TWA
Respirable fraction.
15 mg/m3 TWA Total
dust.
5 mg/m3 TWA
Respirable fraction.
None
None
Engineering controls:
Use positive down-draft exhaust ventilation if general ventilation is insufficient
to maintain vapor concentration below established exposure limits.
Respiratory protection:
Use NIOSH approved respirator if there is potential to exceed exposure
limit(s).
Eye/face protection:
Safety goggles or safety glasses with side shields. Full face protection should
be used if the potential for splashing or spraying of product exists.
Skin protection:
Use nitrile gloves and aprons as necessary to prevent contact. Do not use
PVC, nylon or cotton.
9. PHYSICAL AND CHEMICAL PROPERTIES
Physical state:
Gel
Color:
Clear
Odor:
Irritating
Odor threshold:
1 - 2 ppm
pH:
Not available.
Vapor pressure:
< 0.2 mm hg
Boiling point/range:
> 149 °C (> 300.2 °F)
Melting point/ range:
Not available.
Specific gravity:
1.05
Vapor density:
3
Flash point:
80 - 93 °C (176°F - 199.4 °F) Tagliabue closed cup
Flammable/Explosive limits - lower:
Not available.