Safety Data Sheets (SDS)

IDH number: 1989550
Product name: Loctite Power Grab Ultimate Construction Adhesive
Page 2 of 6
Hazardous Component(s)
CAS Number
Percentage*
Limestone
1317-65-3
60 - 100
Phthalate Ester
Proprietary
10 - 30
Silane derivative
Proprietary
1 - 5
Fatty acid
Proprietary
1 - 5
3-(Trimethoxysilyl)propylamine
13822-56-5
0.1 - 1
Quartz (SiO2) respirable particulates
(RCS) >=10%
14808-60-7
0.1 - 1
* Exact percentage is a trade secret. Concentration range is provided to assist users in providing appropriate protections.
Exposure to moisture during cure will release 1-2% methanol.
4. FIRST AID MEASURES
Inhalation:
Move to fresh air. If symptoms persist, seek medical advice.
Skin contact:
Wash with soap and water. If skin irritation persists, call a physician. Wipe off
paste with paper towel or cloth.
Eye contact:
Flush with copious amounts of water, preferably, lukewarm water for at least
15 minutes, holding eyelids open all the time. If symptoms develop and
persist, get medical attention.
Ingestion:
Do not induce vomiting. If a person feels unwell or symptoms of skin irritation
appear, consult a physician.
Symptoms:
See Section 11.
5. FIRE FIGHTING MEASURES
Extinguishing media:
carbon dioxide, foam, powder, water spray jet, fine water spray
Special firefighting procedures:
Wear protective equipment. Wear self-contained breathing apparatus.
Unusual fire or explosion hazards:
None identified.
Hazardous combustion products:
Carbon dioxide Carbon monoxide.
6. ACCIDENTAL RELEASE MEASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected
personnel.
Environmental precautions:
Do not allow product to enter sewer or waterways.
Clean-up methods:
Refer to Section 8 "Exposure Controls / Personal Protection" prior to clean up.
Store in a partly filled, closed container until disposal. Spilled material will
solidify. Scrape up as much material as possible. Maintain good ventilation for