Manual

3
Secure using 5mm (3/16") bolts (not supplied)
through the 4 mounting feet
TAKE TIME TO LOCATE THE BEST POSITION
If necessary, power the Receiver and move it around
the vehicle until the required performance is achieved.
Operate the Transmitter and observe the Receiver
internal LED’s.
Mount as HIGH as possible
AVOID surfaces with HEAVY VIBRATION
AVOID DIRECT SPRAY from wheels
In a HOT CLIMATE fit in a SHADED position
Cable gland should face DOWN or BACK
Receiver 9206RX and 9306RX shown,
Waterproof to IP67, complete with 3 metres (10 ft) cables
CAUTION
MOUNT RECEIVER
2
or Disconnect Battery
IDENTIFY POWER
CONNECTION POINT
AND ISOLATE SUPPLY
Fuse
Remove fuse
Vehicle batteries contain gasses
which are flammable and explosive.
Wear eye protection and do not lean
over battery while disconnecting. Do
not wear metal jewellery.
!
WARNING
POSITIVE
NEGATIVE
92106RX.01E
7 core cable.
These are
Power Outputs
Transmitter Function I.D.
2 core cable.
These are
Power Inputs
1. The Receiver is designed to carry a maximum of 15 Amps. That is, for example,15 Amps
through one output or 5 Amps each through 3 outputs.
2. Master Output. This can be configured to Continuous or Parallel operation, see overleaf for
details.
3. If Receiver outputs are connected in parallel with an external switching device (wired remote)
the Receiver will instantly switch off when the wired remote is operated
4. Lodar Receivers have an isolation switch for safety, to allow for registering a MUST
replacement Transmitter.
5. Safety Feature. Both the Transmitter and the Receiver will “time out” after 30 minutes of
inactivity. This can be altered, ask your dealer.
1
!
BEFORE YOU START
!
F1
F2
F3
F4
F5
F6
Wiring Instructions for 92 Series & 93 Series 6 Function Receivers
CONNECT
WIRES
4
5
or re-connect Battery
ACTIVATE THE
RECEIVER SUPPLY
Fuse
Replace fuse
Press the Transmitter buttonRESET
to activate the system, and carefully
test each function for correct operation.7
TEST
6
CONNECT TRANSMITTER BATTERY
Batteries generally have to be
disconnected when shipping.
BLACK
RED
GREEN
YELLOW
BROWN
BLUE
WHITE
Output Function 1
Output Function 2
Output Function 3
Output Function 4
Output Function Master
7 Core wire used for:-
Wire Colour
Make notes about the connections made in the boxes
What is the MASTER Output for ?
It is used to operate the pump of an electro-hydraulic
power pack or maybe a clutch pump. It can also be
used for powering a dump valve, master valve etc.
It can be configured to work continuously, that is ON
when SET is pressed and OFF when STOP is
pressed; or in parallel with any output, that is, it is
active only a function is operated. If it is needed with
certain functions only, this can easily be configured.
Output Function 5
Output Function 6
12/24 Volts DC Nominal
Positive Supply
RED
Negative
BLACK
2 Core wire used for:-
Wire Colour
Shown with optional Keypad