12
CaretakerSentry®
v3.10
DLE-200 test box. NEVER LEAVE THE UNIT IN THIS MODE FOR NORMAL OPERATION.
1. Enter (Passcode) – XXXX then “
**
(Default is 1234)
[Voice prompt – Option Mode]
2. Enter – 4
[Voice prompt – DEMO Tradeshow Mode],
1 for YES 3 for NO– FACTORY SETTING
3. Enter either 1 or 3
[V
oice
prompt 1 – YES] [Voice prompt 3 – NO]
4. Enter #(to exit programming mode)
[Voice prompt Programming complete]
5. Slide Programming Switch to “Normal Operation”
[Voice prompt – “Emergency Call Mode”]
Option #6 -- Automatic Call-Back Feature - This feature allows the unit to call a central station, send the
Emergency
Event
information,
hang-up and then automatically answer a return call back. After the base connects
with central station, transmits the Personal Emergency and account info and receives the Kiss-Off tone, the base
hangs up but keeps the communication link active between the pendant/EWC and itself. .It will then answer
the next incoming call and the Customer will speak with the central station with no indication that a callback
has occurred.
1. Enter (Passcode) – XXXX then “
**
(Default is 1234)
[Voice prompt – Option Mode]
2. Enter – 6
[Voice prompt – Automatic Call-back Mode],
1 for YES
3 for NO– FACTORY SETTING
3. Enter either 1 or 3
[V
oice
prompt 1 – YES] [Voice prompt 3 – NO]
4. Enter #(to exit programming mode)
[Voice prompt Programming complete]
5. Slide Programming Switch to “Normal Operation”
[Voice prompt – “Emergency Call Mode”]
Option #7 – Send Restore Message - These are messages that are automatically sent to the central station
to report
the
AC Power or the communication (RF or battery) problem with the Pendant has been restored or
corrected.
1. Enter (Passcode) – XXXX then “
**
(Default is 1234) [Voice prompt – Option Mode]
2. Enter – 7
[Voice prompt – Send restore code to call center,
1 for YES – 3 for NO]
3. Enter either 1 or 3
[Voice prompt 1 – YES]
[Voice prompt 2 – NO] – FACTORY SETTING
4. Enter # (to exit programming mode)
[Voice prompt Programming complete]
5. Slide Programming Switch to Normal Operation
[Voice prompt – “Emergency Call Mode”]
Option #8 - Periodic Test Interval (for automatic check-in with central station)
1. Enter (Passcode) – XXXX then “
**
(Default is 1234)
[Voice prompt – Option Mode]
2. Enter – 8