User's Manual

LTD0211rev16
Page|19
Relays 8Xnormallyopenrelaycontacts.250VAC/5Aeach
Inputs 8Xlowlevelsignalanalog/digitalinputs
Outputs 8Xgeneraluseoutputs,V=24VImax=20mAforeach
LEDs 12XLEDs
Memory
EEPROM 128MB
Flash 128MB
Environmental
Operationaltemperature‐10°C÷+45°C
Storagetemperature‐20°C÷+70°C
Dimensionsandweight
Dimensions LXWXH‐275X159X57mm
Weight 1.29Kg
LFAntennaspowersettings:
ForeachLFantennayoucanconfigureviasoftware,theoutputpoweratrangeofbetween10to100%.
Backupbatteryreplacements:
Warnings:
6. In any case before replacing advice your local supplier technical support or Logitag customers
support.
7. Onlyauthorizedtechniciancanreplacebattery.
8. Disconnectthe unitfromthepowersource.
9. UsebatterywhichapprovedbyLogitagforassemblyattheunit.
10. Batterymustberechargeabletype3.74.2V.
Replacementprocedure:
Disconnecttheunitfrompowersourceandallothercablesconnectiontotheconnectorspanel.
Openthe4screwsofthedevice.
Removethebattery
Connectthenewbattery
Installationinstructions
Installationpositions:
Verticallyplacedonashelforatable,antennasadjustedandpointedtotheceiling.
Wallmount‐Screwedtothewallbyusingthesidebracke ts,antennasadjustedandpointedto
theceiling.
PowerConnection:
Connectthepowerconnectiontothepowersocketandtotheunitat"po wer"connection.
Relayandantennas:
RelayconnectionseeRelay(Drycontact)connectionsection.
AntennasconnecttheantennastoanyportavailableonLFantennasports14.