9. Powersupplyreuiermants
Forsupplyingpowertothedifferentsystemsonemyuse2differentoptions:
LocalLimitedpowersupplysource
Mainpowersupplyunitforseveralunits
9.1 Limitedpowersource:
Whenusinglocalpowersupply,useLPScertifiedtypeequivalentto:
a. EDACp/n
EA10721B-2404
b. MEANWELLp/nGS60A24
9.2 Mainsupplynetwork:
Whenusingmaimspowersupp ly,forsupplyingpowertoseveralunits,youmustfollowthe
followinginstallationrequirements:
a. Usemainpowersupply24Vwithmaximumoutputof40A
b. Theunitmustbecertifiedaccordin gtolocalauthority'srole s.
c. Makesuretheunithasinternaloutputcircuitbreakerwith
shortcircuitandovercurrent
protection.IfnotconnectexternalcertifieddoublepoleDCcircuitbreaker(astheabove)at
ratingsmaximumallowedoutputcurrentofthepowersupply(equalorlowerthanthe
powersupplycurrentoutputratings).
d. Whenconnectingacablebetweenpowersupplytoasystem,
useacablethatcanstandthe
maximumallowedoutputcurrentfromthepowersupply(accordingtolocalauthority's
rules)forexample:
For40Acurrentuse2*10mm
2
cuppercable
For30Acurrentuse2*10mm
2
cuppercable
For25Acurrentuse2*6mm
2
cuppercable
For20Acurrentuse2*4mm
2
cuppercable
e. ToeachendunitconnectacertifieddoublepoleDCcircuitbreakerwithshortcircuitand
overcurrentprotectionwithratingsaccordingtothefollowinglist:
Basestation‐‐‐‐6A.use2*1mm
2
cuppercable
GateLocator/4Channelexciter‐‐‐‐6A.use2*1mm
2
cuppercable
OneChannelExciter‐‐‐‐2A.use2*0.5mm
2
cuppercable
RemoteDoorIndicator‐‐‐‐2A.use2*0.5mm
2