- Travis Owner's Manual Burner DVL Insert EF II

Installation (for qualified installers only) 11
© Travis Industries 4060111 100-01174
Face Sizing
Face Height Width Notes
Rawhide 27” 35-3/4”
Victorian 27 35-3/4”
Rosario 26 35-3/4”
Cambridge 25-7/8” 37-5/8”
Craftsman 27-1/2” 36”
Bungalow 27 32-3/4”
Classic Arched, Artisan 26-1/2” 34-3/4” Side begins arch 3-1/2” below top - 45” radius
Metropolitan 26-1/2” 34-3/4”
Architectural Series 27-7/8” 33-5/8”
Discovery 26 35-3/4’
Wilmington 27 36-1/8”
Face Mounting Brackets Arched, Artisan, Metropolitan, Victorian Lace
Some Arched, Artisan, Metropolitan and Victorian Lace Faces include old brackets that will not
mount to the heater (see illustration below). For these faces, make sure to use the new mounting
brackets (either included with the heater or available through your dealer - SKU 225-20054).
WARNING: When attaching the Victorian Lace Face, do not over-tighten the screws. Over-
tightening the screws may damage the face simply tighten the screws until they contact the face.
New Brackets Old Brackets
Install the face mounting
brackets with the included nuts.
NOTE: The brackets install into the
lower pair of holes on the insert.
NOTE: The brackets
install with this pair of
closely spaced flanges at
the top.