User manual
Start-up
- 45 -01.10
Main parameters13.5 
Parameter
Symbol
Code
Factory 
setting
Range
Wire feed in % 
(positive correc-
tion)
0
-80.. 
+99
Wire feed in % 
(negativecorrec-
tion)
Displayed as correction value for settings at 
turning knob 61.
Wire feed in 
m/min
- -
0,5.. 
25
Displayed as speed value in m/min after 
setting with turning knob 61.
Material thick-
ness (at selected 
characteristic 
line)
- - -
Must-value wel-
ding voltage (in 
manual mode, 
only Control Pro)
V
- - -
Welding step (in 
manual mode) - -
1..6, 
1..7 
1..12
Main parametersTab. 6: 
Secondary parameters13.6 
Press the mode key 60 for at least 2 se- Â
conds.
The 7-segment display 47 displays  the  9
secondary parameter code and value al-
ternately (BasicPlus).
The 7-segment display 47 displays the se- 9
condary parameter value, the 7-segment 
display  55  displays  the  secondary  para-
meter code (ControlPro).
Press the mode key 60 until the required  Â
secondary parameter code is displayed.
Set the required secondary parameter va- Â
lue using turning knob 61.
Exit the secondary parameter by pressing  Â
the mode key 60 for at least 2 seconds.
Parameter Code
Factory 
setting
Mode
Range
2-stroke
4-stroke
Spot
Interval
Gas pre-ow
0,1 s
x x x x
0,0...10,0 s
Creep in 
speed
1,0 m/min
x x x x
0,5...15,0 
m/min
Spot welding 
time
1,0 s
x
0,1...10,0 s
Backburn time
100 %
x x x x
0...300 %
Gas post-o
0,5 s
x x x x
0,1...20,0 s
Intervalltime 
ON
1,0 s
x
0,1...10,0 s
Interval time 
OFF
0,2 s
x
0,1...1,0 s
Software 
Version
- x x x x
Must-value 
welding vol-
tage instead 
of material 
thickness
off
x x x x
off/on
Secondary parametersTab. 7: 