User manual

Start-up
- 45 -01.10
Main parameters13.5
Parameter
Symbol
Code
Factory
setting
Range
Wire feed in %
(positive correc-
tion)
0
-80..
+99
Wire feed in %
(negativecorrec-
tion)
Displayed as correction value for settings at
turning knob 61.
Wire feed in
m/min
- -
0,5..
25
Displayed as speed value in m/min after
setting with turning knob 61.
Material thick-
ness (at selected
characteristic
line)
- - -
Must-value wel-
ding voltage (in
manual mode,
only Control Pro)
V
- - -
Welding step (in
manual mode) - -
1..6,
1..7
1..12
Main parametersTab. 6:
Secondary parameters13.6
Press the mode key 60 for at least 2 se- Â
conds.
The 7-segment display 47 displays the 9
secondary parameter code and value al-
ternately (BasicPlus).
The 7-segment display 47 displays the se- 9
condary parameter value, the 7-segment
display 55 displays the secondary para-
meter code (ControlPro).
Press the mode key 60 until the required Â
secondary parameter code is displayed.
Set the required secondary parameter va- Â
lue using turning knob 61.
Exit the secondary parameter by pressing Â
the mode key 60 for at least 2 seconds.
Parameter Code
Factory
setting
Mode
Range
2-stroke
4-stroke
Spot
Interval
Gas pre-ow
0,1 s
x x x x
0,0...10,0 s
Creep in
speed
1,0 m/min
x x x x
0,5...15,0
m/min
Spot welding
time
1,0 s
x
0,1...10,0 s
Backburn time
100 %
x x x x
0...300 %
Gas post-o
0,5 s
x x x x
0,1...20,0 s
Intervalltime
ON
1,0 s
x
0,1...10,0 s
Interval time
OFF
0,2 s
x
0,1...1,0 s
Software
Version
- x x x x
Must-value
welding vol-
tage instead
of material
thickness
off
x x x x
off/on
Secondary parametersTab. 7: