User manual
Messages
- 46 - 01.10
Special functions13.7 
Gas test
Turn the unit OFF using main switch 9. Â
Press the torch key and keep it pressed. Â
Turn the unit ON using main switch 9. Â
The solenoid valve of the unit  will go on  9
and the gas supply can be tested/adjus-
ted. The function is active for 30 seconds 
and  will  be  automatically  stopped.  Re-
pressing  the  torch  key.  can  interrupt  the 
gas test.
Fan test
Turn the unit ON using main switch 9. Â
The fan will start for function purposes. 9
Operation panel test
Press the mode key 60 for at least 5 se- Â
conds.
All operation displays will ash for approx.  9
20 seconds.
Reset setting 13.8 
Master reset
Attention  All personal settings 
will be lost.
All welding  and secondary  para-
meters are reset to their factory 
settings.
Turn the unit OFF using main switch 9. Â
Press the mode key 60 and keep it pres- Â
sed.
Turn the unit ON using main switch 9. Â
All  symbols  and  displays  will  light  up  9
shortly to conrm reset.
i
During operational faults/malfunction , the 
7-segment display 47 displays an error 
code.
As long as there is an error code 
on display welding is not possible.
i
Messages14 
Code Error description Note Rectication
E00 no program Selected programme number does 
not exist.
Select a different cha-
racteristic line
Instead of material thickness „--- " 
is displayed and by pressing the 
torch key „E00" shows up. Welding 
is not possible at activated charac-
teristic line and set welding step.
Select a different wel-
ding step