- 46 - 01.10
Special functions13.7
Gas test
Turn the unit OFF using main switch 9. Â
Press the torch key and keep it pressed. Â
Turn the unit ON using main switch 9. Â
The solenoid valve of the unit will go on 9
and the gas supply can be tested/adjus-
ted. The function is active for 30 seconds
and will be automatically stopped. Re-
pressing the torch key. can interrupt the
gas test.
Fan test
Turn the unit ON using main switch 9. Â
The fan will start for function purposes. 9
Operation panel test
Press the mode key 60 for at least 5 se- Â
conds.
All operation displays will ash for approx. 9
20 seconds.
Reset setting 13.8
Master reset
Attention All personal settings
will be lost.
All welding and secondary para-
meters are reset to their factory
settings.
Turn the unit OFF using main switch 9. Â
Press the mode key 60 and keep it pres- Â
sed.
Turn the unit ON using main switch 9. Â
All symbols and displays will light up 9
shortly to conrm reset.
i
During operational faults/malfunction , the
7-segment display 47 displays an error
code.
As long as there is an error code
on display welding is not possible.
i
Messages14
Code Error description Note Rectication
E00 no program Selected programme number does
not exist.
Select a different cha-
racteristic line
Instead of material thickness „--- "
is displayed and by pressing the
torch key „E00" shows up. Welding
is not possible at activated charac-
teristic line and set welding step.
Select a different wel-
ding step