User manual

Messages
- 47 -01.10
Code Error description Note Rectication
E01 Excessive tempe-
rature
The equipment has been overhea-
ted
Allow the system to cool
down in standby, check
the ventilation system
E02 Mains overvoltage Mains input voltage too high Check mains voltage
E03 Overcurrent Output current is too high / Perma-
nent short circuit
Service verständigen
E06 Overvoltage Output voltage too high Inform Service
E07 EEProm checksum
error
Setting data faulty or missing Switch the equipment
off and on again
E08 Wire feed Too high power intake from wire
feed motor (Motor Over-Current)
Blow down torch pac-
kage with pressured air
and check pressure on
wire feed rolls.
E09 Voltage-measuring Voltage measuring system defective Service verständigen
E13 Temp. sensor error Thermal sensor not ready for ope-
ration
Inform Service
E14 Supply voltage internal supply voltage too low
(18V~ / 24V-)
Check mains voltages
E15 Power measuring Fault at power measuring Service verständigen
E16 Supply voltage
motor and main
contactor
Internal supply voltage is too little
(42V~ / 60V-)
Check power supply
voltage
E17 Peripherie overload/
short circuit
Short circuit in torch or hose packa-
ge, gas valve or feed line, wire run
key or line
Test alt. exchange the
connected torch
E18 Error conguration Faulty or wrong pc-board,
wrong software system played
Inform Service
MessagesTab. 8: