User manual
Technical data
- 50 - 01.10
Repair and maintenance16 
Please  heed  the  current  safety 
and  accident  prevention  regu-
lations during  all  maintenance 
and repair work.
Check regularly16.1 
Check  the  following  points  for  damage 
before starting up the welding machine:
Mains plug and cable –
Welding torch and connections –
Ground cable and connection –
Blow out the welding machine every two 
months. 
Switch the machine off Â
Disconnect the mains plug Â
Unscrew both side panels of the unit Â
Blow out the welding machine with dry, low  Â
pressure  compressed  air.  Avoid  blowing 
directly on the electronic components from 
a short distance, to prevent damage
Screw the two side panels onto the machi- Â
ne back again
Never make repairs or technical 
changes yourself. 
In  this  case  the  manufacturer’s 
warranty is no longer valid.
If  you  experience  problems  or 
need repairs, contact a dealer au-
thorised by Lorch. 
Torch care16.2 
Remove the weld spatter from inside the  Â
gas nozzle using suitable tongs.
Spray the inside surface of the gas nozzle  Â
with a releasing agent, or use nozzle pro-
tection paste.
This will prevent weld spatter from being  9
burnt on. 
i
Technical data
1
M 150 CuSi 
BasicPlus
M 150 CuSi 
ControlPro
M 170 
BasicPlus
2
M 210 
BasicPlus
2
M 210 
ControlPro
2
M 250 
BasicPlus
M 250 
ControlPro
M 300 
BasicPlus
M 300 
ControlPro
Welding
Welding range (I
2min
..I
2max
) A 15..150 15..150 25..170 25..210 25..210 30..250 30..250 30..300 30..300
Welding range (U
2min
..U
2max
) V 14,8.. 
21,5
14,8.. 
21,5
15,3.. 
22,5
15,3.. 
24,5
15,3.. 
24,5
15,5.. 
26,5
15,5.. 
26,5
15,5.. 
29,0
15,5.. 
29,0
No-load voltage
V 14,4.. 
26,9
14,4.. 
26,9
16,7.. 
38,0
14,5.. 
40,3
14,5.. 
40,3
16,3.. 
35,1
16,3.. 
35,1
16,3.. 
40,2
16,3.. 
40,2
Voltage setting
steps
7 7 6 12 12 12 12 12 12
Slope characteristic constant voltage characteristic line
ED 100 % 
A 100 100 70 75 75 115 115 135 135
ED 60 % 
A 120 120 85 90 90 140 140 175 175
Technical data17 