Operation Manual

137
User Manual
AUXINI/O
AUX-IN I/O CABLE
AUX-IN I/O CABLE
1
2
3
4
5
6
7
8
PIN CABLE COLOR FUNCTION
BLACK
RED
WHITE
GREEN
GRAY
YELLOW
BROWN
BLUE
GND/COMMON
POWER OUTPUT+
Used by C-COM
Used by C-COM
OUTPUT 5+
Used by C-COM
INPUT 5+
OUTPUT EXTERNAL ALARM+
(10-35 Vdc)
Fig. 7.4c - C-COM Connection on Port 4 for PANORAMIC 8 HD
QUICK DISCONNECT BRACKET CABLE
DESCRIPTIONWIRE COLOR
BLACK
RED
WHITE
GREEN
YELLOW
POWER SUPPLY GND
POWER SUPPLY+
C-COM
SIGNAL RETURN
C-COM
POWER GND
POWER +10-35Vdc
INPUT1+
SIGNAL RETURN-
OUTPUT1+
FUNCTION
C-COM GSM Plus CABLE
WIRE COLOR
BLACK
RED
WHITE
GREEN
YELLOW
GND
POWER SUPPLY+
C-COM TX+
C-COM TX-
C-COM RX+
FUNCTION
Fig. 7.4d - C-COM Connection on Port 1 for PANORAMIC 8 XL/HD WITH PORT 4 AUX IN I/O CONNECTOR BUSY
for PANORAMIC 8 HD FISH
7.5 TROUBLESHOOTING
The following is a brief guide to some of the problems you may experience
while using the chart plotter with common solutions.
7.5.1 PROBLEMS AND SOLUTIONS
The chart plotter does not turn On — Make sure that the correct voltage (10-35
volt dc) is present. Check also that the polarity is correct. Refer to the Par. 2.2.
The chart plotter does not turn Off — If, after a 'POWER' pressure (for at least 3
seconds) the chart plotter does not turn Off, then turn Off the voltage.
The chart plotter does not respond to any command — Try to turn Off, and then
turn On. If the problem persists, erase the memory (see Par. 6.6.1).
The chart plotter does not get a valid fix — Make sure that no metal obstacle is
placed around the chart plotter acting as a shield for the antenna. If, after 15 minutes,
the chart plotter does not get the fix, turn it Off and On again.
The chart plotter screen becomes very dark after a long exposure to direct sun-
light — Control the contrast (see Par. 2.3).