Operation Manual

130
User Manual
6.5.8 INTERFERENCE REJECTION
Selects a filter to remove interference from other Fish Finders.
'MENU' + "INTERFER REJECTION" + 'ENTER'
6.5.9 SENSITIVITY
The Sensitivity menu is accessible both from the Fish Finder Setup menu
and by pressing 'ENTER' when in Fish Finder pages. All settings in the Sensitivity
menu are related to the Frequency selected.
'MENU' + "SENSITIVITY" + 'ENTER'
6.5.9.1 Frequency O
NLY
IN
THE
D
UAL
F
REQUENCY
PAGE
Allows you to select the Frequency to which the Sensitivity parameters are
applied.
Note
The Frequency value is only displayed: to select the desired frequency see the previous Par. 6.5.7.
6.5.9.2 Gain
Allows you to control the Gain of the unit's receiver. To see more details on
the screen, increase the receiver sensitivity by selecting a higher gain percentage. If
there is too much detail or if the screen is cluttered, lowering the sensitivity may
increase the clarity of the display.
6.5.9.3 STC
Sensitivity Time Constant: it is a time varying gain curve which attenuates
the sonar receiver gain in shallow water, increasing the gain gradually as the depth
increases. This is for the purpose of filtering out surface clutter.
6.5.9.4 STC Length
If STC is Custom, it is possible to change the Length of the Sensitivity Time
Constant.
6.5.9.5 STC Strength
If STC is Custom, it is possible to change the Strength of the Sensitivity
Time Constant.
6.5.9.6 Surface Noise Filter
This function implements an advanced time varying filter that allows