SDS
SHENZHEN KELONGYUAN ELECTRONICS CO., LTD.
CR 1220 Battery JAN.2014 Kelongyuan
Page 1 of 6
MATERIAL SAFETY DATA SHEET (MSDS)
SHENZHEN KELONGYUAN ELECTRONICS CO., LTD.
MSDS No: 201401 CR1220
Product Name: Lithium-Manganese Button Cell Battery
(Lithium Metal Battery)
Issued and Revised Date: 01-JAN-2014
1. PRODUCT AND COMPANY IDENTIFICATION
Product Name: Lithium-Manganese Button Cell Battery
Applicable Models/Sizes: CR 1220
Contact Point:
SHENZHEN KELONGYUAN ELECTRONICS CO., LTD.
Add: 2F, BUILDING 52, BAO TIAN INDUSTRIAL PARK, XI XIANG, BAO
AN, SHENZHEN, CHINA
TEL: +86-755-23701286 FAX: +86-755-23708669
URL :Http://www.kelongyuan.com/ E-mail: szklydz@163.com
2. HAZARDS IDENTIFICATION
All chemical materials of lithium-manganese button cell battery cell are stored in a
hermetically sealed metal case, designed to withstand temperatures and pressures
encountered during normal use. There is no physical danger of ignition or explosion and
chemical danger of hazardous materials' leakage during normal use. However, if
exposed to a fire, added mechanical shocks, decomposed, added electric stress by miss-
use, the gas release vent will be operated and hazardous materials may be released.
Potential Health Effects:
Cobalt and Cobalt compounds are considered to be possible human carcinogen(s).
These chemicals may cause allergic skin sensitization (rash) and irritate eyes, skin, nose,
throat, respiratory system.
Since electrolyte is flammable liquid, it does not bring close to fire. It may cause
moderate to severe eye irritation, dryness of the skin. Breathing of its mist, vapor or
fume may irritate nose, throat and lungs. Exposure of electrolyte material in the area
which contains water may generate hydrofluoric acid, which can cause immediate burns
on skin, severe eye burn. The ingestion of electrolyte can cause serious chemical burns
of mouth, esophagus and gastrointestinal tract.