User Guide

Table Of Contents
. . . . .
CODELOG MODE
1)Config## > 3)Freq/Ch
Guide to the SRX 600 receiver Rev A #10112 Chapter 5 - - Page 55
the master table cannot contain frequencies that reference the same channel
number or frequencies that are separated by less than 1kHz.
A DDING A FREQUENCY/ CHANNEL
Enter a frequency into the receiver via Codelog > 1)Config## > 3)Freq/CH >
1)Add > 1)Radio or 2)Acoustic. The display first prompts for the frequency to be
entered. The decimal point is not automatically provided; use the decimal key.
After the full frequency value has been entered, the display automatically goes to
the Set Ch# (set channel number) page. Enter a number for the channel that will
be assigned to the frequency entered. After entering a channel number, press the
ENTER key to apply the changes. COntinue to add frequencies+channels in this
manner.
Frequencies cannot be changed through the keypad after they are added;
they can only be deleted or disabled.
No two Frequencies have the same channel number. Assigning a channel
number provides an easier way of referencing frequencies. For example, it is
easier to say “scan channel 3” than it is to say “scan frequency 151.360”.
D ELETING A FREQUENCY/ CHANNEL
It is important to note that because frequencies in a frequency table are also
copied into the master table, they can be deleted from a frequency table and still
exist in the master table.
A frequency can be deleted from a frequency table via Codelog > 1)Config## >
3)Freq/CH > 2)View/Modify > 1)Del.
E NABLING AND DISABLING A FREQUENCY/ CHANNEL
Individual frequencies in a frequency table can be enabled (available for
scanning) or disabled (skipped), whereby during a scan a frequency can be
temporarily removed from the scan cycle until it is needed again.
The receiver only scans frequencies that are enabled. By default all
frequencies entered are considered enabled.