To calibrate an EP-10 Fuel Flow: 
10. If calibration is necessary, press MENU|MENU, select NMEA 2000 and 
press 
ENT. 
11. Highlight 
FUEL MANAGEMENT and press ENT. 
12. Select 
TANK LOCATION and press ENT to choose the location of the tank 
connected to selected fuel flow. Press 
ENT. 
13. Highlight 
FILL  TANK and press ENT. The following message will ap-
pear: Are you sure you wish to Fill Tank? Select 
YES and press ENT. 
14. The following message will appear: Do you wish to re-calibrate the 
device? Select 
YES and press ENT. 
15. Repeat these steps for each EP-10 Fuel Flow you want to calibrate. 
To Reset Calibration: 
1. Press MENU|MENU, select NMEA 2000 and press ENT. 
2. Highlight 
FUEL MANAGEMENT and press ENT. 
3. Highlight 
ENGINE SELECT and press ENT. The Engine Select menu will 
appear with up to four options: All Engines, Port, Center and Star-
board. Selecting All Engines will reset calibration for all engines back 
to factory defaults. 
4. Select All Engines or the engine connected to the desired device and 
press 
ENT. 
5. Highlight 
RESET CALIBRATION and press ENT. The following message 
will appear: Are you sure you wish to Reset Calibration? 
6. Highlight 
YES and press ENT. Press EXIT repeatedly to get back to the 
main display. 
EP-15 Fluid Level Calibration 
The default calibration for the EP-15 Fluid Level is just as accurate as 
standard fluid level gauges. If, however, the tank has an irregular 
shape or greater accuracy is needed, calibration is recommended. There 
are three calibration options: 2-Point, 3-Point and 5-Point. 
2-Point Calibration 
A 2-point calibration is best suited for rectangular or square-shaped 
tanks, where the capacity of the top half of the tank matches the capac-
ity in the lower half of the tank. In a two-point calibration, you will set 
two points, one each for empty and full levels. You can begin calibra-
tion at either of the two points, but we recommend starting with an 
empty tank. You will fill the tank to complete calibration. 
1. Press 
MENU| MENU, use ↓ ↑ to select NMEA 2000 and press ENT. 
2. Highlight 
BUS SETUP and press ENT, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page. 