Operating Instructions and Installation Instructions
227 
1. Press 
MENU| MENU, use ↓ ↑ to select NMEA 2000 and press ENT. 
2. Highlight 
BUS SETUP and press ENT, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page. 
3. Select the desired EP-15 Fluid Level and press 
ENT. 
4. Press ↓ to select 
CALIBRATE and press ENT. The Device Calibration 
menu will appear. 
5. Highlight 
NUM PTS, press ENT and select 5. Press ENT. 
6.  Make sure your tank is empty, then  highlight  FLUID  LEVEL  and press 
ENT
. Select EMPTY LEVEL and press ENT. 
7. 
Select  CALIBRATE  and press ENT. The following message will appear: 
Empty Level Calibration Completed. Press 
ENT. 
8. 
Add 1 quarter tank of fuel, highlight FLUID LEVEL and press ENT. Select 
1
 QTR LEVEL and press ENT. 
9.  Select  C
ALIBRATE and press ENT. The following message will appear: 1 
Qtr Level Calibration Completed. Press 
ENT. 
10. Add another quarter tank of fuel, which should raise the fuel level 
to half a tank. Highlight
 FLUID LEVEL and press ENT. Select HALF LEVEL and 
press
 ENT. 
11. 
Highlight  CALIBRATE  and press ENT. The following message will ap-
pear: Half Level Calibration Completed. Press 
ENT. 
12. Add another quarter tank of fuel, which should raise the fuel level 
to 3 quarters of a tank. Highlight
 FLUID LEVEL and press ENT. Select 3 QTR 
LEVEL and press ENT. 
13. 
Select CALIBRATE and press ENT. The following message will appear: 3 
Qtr Level Calibration Completed. Press 
ENT. 
14. Top off the tank, highlight
  FLUID LEVEL  and press  ENT.  Select  FULL 
LEVEL and press ENT. 
15. Select  CALIBRATE and press ENT. The following message will appear: 
Full Level Calibration Completed. Press 
ENT, then press EXIT repeat-
edly to get back to the main display. 
Fuel Flow Calibration in a Suzuki Engine Interface 
The default calibration for the Suzuki Engine Interface is adequate in 
most cases, but if Fuel Used readings are off by more than 3 percent, 
calibration is recommended. 
To check engine interface accuracy: 
Select Fuel Used to be shown as Overlay Data on your unit's main dis-
play. Refer to the Overlay Data segment of this manual for instructions 
on how to select Fuel Used data as Overlay Data. 