Installation Guide

CONDITION
Snug
Flush
Visible Fiber
Countersunk
1/16”-1/8” (2 mm-3 mm)
Countersunk
more than 1/8” (3 mm)
CORRECTION
OK
OK
Paint
Apply Sealant
Apply Sealant &
re-nail
TRIM & FASCIA 190, 440, 540 & 2000 SERIES
Install over wood structural panels a minimum 7/16 Category
with an APTrademark that contains the consensus Standard
DOC PS 1 or PS 2. Exception: LP® FlameBlock® Fire-Rated OSB
Sheathing.
Fastener length: Long enough to fully penetrate wood
structural panel sheathing by at least 1/4 inch. Ensure that the
ring shanks of the fastener fully engage the wood structural
panel sheathing. (Diagram 3a)
Fastener placement: A minimum 3/4 inch down from top edge
of siding. Fasteners shall be placed 1 inch from ends, excluding
the width of the shiplap. (Diagram 3a)
Fastener spacing: Space ring shank nails a maximum of 8 inches
o.c. across the top of siding. (Diagram 4a)
Use a minimum 0.092 inch diameter shank, hot-dipped
galvanized or stainless steel ring shank nail. Fasteners shall be
corrosion resistant and capable of preventing rust, stain and
deterioration under normal outdoor environmental conditions
for a period of no less than 50 years.
Table 3a
PREPARATION
General Application Equipment
GENERAL REQUIREMENTS (CONTINUED)
INSTALLATION
Fastening Instructions - Sheathing Only
LP SmartSide Perfection Shingle
3
Fasteners: Minimum 0.092 inch diameter,
hot-dipped galvanized (ASTM A-153) or
stainless steel ring shank nail. Apply and
correct overdriven nails as shown in Table 3a.
Sealant: Use an exterior-quality, non-
hardening, paintable sealant. Use a Class 25 or
higher exterior sealant meeting the ASTM C920
Standard for Specication for Elastomeric Joint
Sealants. Follow the sealant manufacturer’s
instructions for application.
Paint: An exterior-quality 100% acrylic latex
paint, specially formulated for use on wood
and engineered wood substrates, is highly
recommended. Semi-gloss or satin nish
oil or alkyd paints are acceptable. For at
alkyd paint, please check with the coating
manufacturer for their recommendations for
use on composite wood siding.
Ring Shank Diameter ≥ 0.092” Hot-Dipped Galvanized
3a
Nail fully
penetration
sheathing
at least 1/4”
(6 mm)
3/4” min.
(19 mm)
1-1/2” min.
(38 mm)
overlap
Sheathing
Water-
Resistive
Barrier
Reveal 5-1/2”
to 6-1/2”
(140 mm
to 165 mm)
• For the cleanest cut and longer blade life, a ne-tooth carbide tipped blade is recommended.
Siding is manufactured with a special edge coating which reduces moisture-related issues. If siding is ripped you must take
special care to prime, paint and seal all exposed wood ber as described in the nishing section.
Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or prenished surface.
Do not miter edges.
Cutting