Instructions / Assembly
TRIM & FASCIA 190, 440, 540 & 2000 SERIES
APPLICATION
INSTRUCTIONS
• Trim may be installed as fascia, without sub-fascia, if it is 440 Series or larger and the following specications are met:
- Trim and Fascia must be greater than 5 inches wide.
- Maximum roof truss or rafter spacing of 24 inches on-center.
• If trim is installed directly to outlookers on an overhanging rake, the outlookers must be installed edgewise and must be spaced no wider
than 24 inches o.c. (See diagram 9a)
• 190 Series trim and fascia products MUST BE supported with solid wood
sub-fascia.
• Trim and Fascia are not designed for structural applications and cannot
be used in the structural design of a roof assembly.
• Exposed ying or suspended barge, rake or fascia tails are not covered
under the LP SmartSide trim limited warranty if trim is extended beyond
the protection of the roof system. If LP SmartSide trim is extended
beyond the protection of the roof system, cap the top of the trim with a
metal coping that is integrated with the roong system.
(See diagram 9b)
• Install drip-edge to prevent water buildup behind fascia and trim.
(See diagrams 2c and 9c)
AT CORNERS: (See diagram 9d)
• All joints must be supported by framing.
• Do not nail from the face of one trim member into the edge of another.
• Do not miter cut the corner joint.
INSTALLATION
FASCIA AND RAKE BOARDS
9c
9d
9a
9b
Ridge
Barge Rafter
A ladder of outlookers
the same dimension as
rafters at 24” o.c. max.
Metal
Coping
1” Gutter
Clearance
3/16” space
with sealant
First Common
Rafter
End or
Verge Rafter
2x or 4x Outlookers
Fascia
First Common
Rafter
Barge Rafter
Drip-edge
Fascia
3/16” space
with sealant
Sot
Trim
9