Installation Instructions

1
A - Cedar Shake Lap Siding
Store o the ground well supported, on a  at well-drained surface.
(Diagram 1a)
Additional support may be required to achieve a safe clearance
from the ground.
• Store products under a roof or separate waterproof covering.
(Diagram 1a)
When the waterproof covering is removed, cut all unit banding.
• Keep siding clean and dry. Inspect prior to installation.
General Information
• At the time of manufacture, siding meets or exceeds the performance standards set forth in ICC-ES AC321 and has achieved
code recognition under ESR-1301 and CCMC 11826-L, APA recognition under PR-N124, and HUD-MR1318c. For copies of
these reports, call LP Customer Support at 800-648-6893 or go online at https://lpcorp.com/resources/product-literature/#.
LP’s application instructions describe the minimum requirements needed to assure LP® SmartSide® Limited Warranty coverage.
Failure to follow the LP application instructions could result in reduced product service life and may lead to denial of coverage
under the LP SmartSide Limited Warranty.
Diagram 1a
A
®
LP SMARTSIDE CEDAR SHAKE
PRIMED LAP SIDING
• Minimum 6 inch (152 mm) clearance must be maintained between siding and  nish grade (ground cover).
Siding applied adjacent to porches, patios, walks, roofs or other hard  nished surfaces must have a clearance of at least 1 inch
(25 mm) above that surface. (Diagram 2a)
Siding must not be in direct contact with masonry, concrete, brick, stone, stucco or mortar. Backer rod is recommended to
properly space materials at these locations.
Apply siding in a manner that prevents moisture intrusion and water accumulation.
All wood substrate exposed to the weather must be sealed in a manner the prevents moisture intrusion and water accumulation.
- Seal ALL exposed cuts of siding and trim. Field spray applied coatings on cuts are not recommended.
- Sealing can be accomplished by applying a coating or sealant according to the manufacturers requirements.
• Do not use staples.
Siding is designed to be installed directly to wood structural panel wall sheathing, or can be installed directly to studs
spaced a maximum of 16 inches (406 mm) on-center (o.c.), or over rigid foam insulation or to furring strips over concrete/
masonry walls.
Before You Begin
ON SITE STORAGE
PREPARATION
APPLICATION INSTRUCTIONS