Installation Instructions
1
A - Cedar Shake Lap Siding
• Store o the ground well supported, on a at well-drained surface.
(Diagram 1a)
• Additional support may be required to achieve a safe clearance
from the ground.
• Store products under a roof or separate waterproof covering.
(Diagram 1a)
• When the waterproof covering is removed, cut all unit banding.
• Keep siding clean and dry. Inspect prior to installation.
General Information
• At the time of manufacture, siding meets or exceeds the performance standards set forth in ICC-ES AC321 and has achieved
code recognition under ESR-1301 and CCMC 11826-L, APA recognition under PR-N124, and HUD-MR1318c. For copies of
these reports, call LP Customer Support at 800-648-6893 or go online at https://lpcorp.com/resources/product-literature/#.
• LP’s application instructions describe the minimum requirements needed to assure LP® SmartSide® Limited Warranty coverage.
• Failure to follow the LP application instructions could result in reduced product service life and may lead to denial of coverage
under the LP SmartSide Limited Warranty.
Diagram 1a
A
®
LP SMARTSIDE CEDAR SHAKE
PRIMED LAP SIDING
• Minimum 6 inch (152 mm) clearance must be maintained between siding and nish grade (ground cover).
• Siding applied adjacent to porches, patios, walks, roofs or other hard nished surfaces must have a clearance of at least 1 inch
(25 mm) above that surface. (Diagram 2a)
• Siding must not be in direct contact with masonry, concrete, brick, stone, stucco or mortar. Backer rod is recommended to
properly space materials at these locations.
• Apply siding in a manner that prevents moisture intrusion and water accumulation.
• All wood substrate exposed to the weather must be sealed in a manner the prevents moisture intrusion and water accumulation.
- Seal ALL exposed cuts of siding and trim. Field spray applied coatings on cuts are not recommended.
- Sealing can be accomplished by applying a coating or sealant according to the manufacturer’s requirements.
• Do not use staples.
• Siding is designed to be installed directly to wood structural panel wall sheathing, or can be installed directly to studs
spaced a maximum of 16 inches (406 mm) on-center (o.c.), or over rigid foam insulation or to furring strips over concrete/
masonry walls.
Before You Begin
ON SITE STORAGE
PREPARATION
APPLICATION INSTRUCTIONS