Installation Instructions

3
TRIM & FASCIA 190, 440, 540 & 2000 SERIES
Install over wood structural panels a minimum 7/16 Category
with an APA® Trademark that contains the consensus Standard
DOC PS 1 or DOC PS 2.
- Exception: LP® FlameBlock® Fire-Rated OSB Sheathing.
Fastener size: Use a minimum 0.092 inch diameter ring shank
nail, hot-dipped galvanized (ASTM A153) or equivalent. Fasteners
shall be corrosion resistant and capable of preventing rust,
stain and deterioration under normal outdoor environmental
conditions for a period of no less than 50 years.
Fastener placement: A minimum 3/4 inch (19 mm) down from
top edge of siding. Fasteners shall be placed 1 inch (25 mm)
from ends. (Diagram 3b & 4b)
Fastener length: Long enough to fully penetrate wood
structural panel sheathing by at least 1/4 inch (6 mm). Ensure
that the ring shanks of the nail fully engage the wood structural
panel sheathing. (Diagram 3b)
Fastener spacing: Space ring shank nails a maximum of 8 inches
(203 mm) o.c. across the top of siding. (Diagram 4a)
Apply siding to wall assembly directly to wood structural panel
sheathing.
Begin by nailing a starter strip approximately 3/8 inch (10 mm)
thick x 1-1/2 inches (38 mm) wide  ush with bottom edge of sill
plate.
Diagram 3a
General Application Equipment
Fastening Instructions - Sheathing Only
Fasteners: Apply and correct overdriven
fasteners as shown in Diagram 3a.
Sealant: Use an exterior-quality, non-
hardening, paintable sealant. Use a Class
25 or higher exterior sealant meeting the
ASTM C920 Standard for Speci cation for
Elastomeric Joint Sealants. Follow the sealant
manufacturers instructions for application.
Paint: A premium quality exterior 100% acrylic
latex paint, specially formulated for use on
wood or engineered wood substrates is highly
recommended.
Semi-gloss or satin  nish oil
or alkyd paints are acceptable. For  at alkyd
paint, check with the coating manufacturer to
ensure it is suitable for engineered wood siding.
Diagram 3b
• For the cleanest cut and longer blade life, a  ne-tooth carbide tipped blade is recommended.
Siding is manufactured with a special edge coating which reduces moisture intrusion. If siding is ripped you must take special
care to prime, paint and seal all exposed wood  ber as described in the Finishing Instructions on page 8.
Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or pre nished surface.
Do not miter edges.
Cutting
PREPARATION
INSTALLATION
Nail fully
penetrate
sheathing
at least
1/4” (6 mm)
3/4” min.
(19 mm)
Reveal:
max. 10”
(254 mm)
to min. 7”
(178 mm)
1” min.
(38 mm)
overlap
Sheathing
WRB
Snug
CONDITION CORRECTION
OK
Flush
OK
Visible fiber
Paint
Apply sealant
Countersunk
more than 1/8"
Apply sealant
and re-nail
Countersunk
1/16" - 1/8"
LP® SmartSide® Cedar Shake