Installation Guide

N I






-








-


DO
• Primeandpaintallexposedsurfacesincludingalldrip
edgesorwherewaterwillhang.
 

F I
Applicationinstructions(cont.)









-


-




LPSiding
Minimum1"clearance
betweentrimandroong
Cleanrain
gutter
-

 




T
Donotruntrimorsidinginside
ofthekickoutashing
3
/
8
in. from edge
1
/
8
in. gap
Single row of nails
Nail
penetration
min. 1-
1
/
2
in.
Alignment bead
Figure 2
Double row of nails
1
/
8
in. gap
Alignment bead
Figure 1
1 in. from edge
 




 

DO NOT USE
 
 
 

HANDLE PREFINISHED LP SMARTSIDE PRODUCTS WITH
EXTREMECAREDURINGSTORAGEANDAPPLICATION.TOUCH
UP ANY DAMAGE TO THE FINISH THAT MAY OCCUR DURING
APPLICATIONPERPREFINISHERSSPECIFICATIONS.