Logic Use's Guide Network Adapter SI40919O,LSI40919LO,LSI40919H,LSI40919LH,LSI44929O,LSI44929LO, LSI44929H,LSI44929LH,ITI7004G2-LC

Open Boot BIOS 4-9
Ver. 2.0 Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Target 6
Unit 0 Removable Read Only device PLEXTOR CD-ROM PX-20TS
If the Fibre Channel devices on your LSI Logic/IntraServer adapter are
not identified by your system, check the following:
Is the Fibre Channel enclosure powered ON?
Does the LED on the adapter indicate LINK? (Note that LINK is valid
only after the device is probed.)
Does the LED on the switch or remote enclosure indicate LINK?
Does the LINK-SPEED parameter selected by the adapter match
that of the bus (1G, 2G,orAuto)?
If you do not see disks, the following additional debug information may
help to identify the problem.
4.8.3 Verifying Correct Installation
Use this procedure to verify installation of your Fusion-MPT adapter in
the system:
Step 1. Power on the system.
Step 2. When the banner is displayed, press the Stop-A keys to
interrupt the boot process and stop at the ok prompt.
Step 3. Use the show-devs command to list the system devices. You
should see an output similar to the following:
ok show-devs
/SUNW,UltraSPARC-III@0,0
/virtual-memory
/memory@m0,0
/aliases
/options
/openprom
/chosen
/packages
/upa@8,480000/SUNW,ffb@0,0
...
/pci@8,700000/IntraServer,fc@2
/pci@8,700000/IntraServer,fc@1,1
/pci@8,700000/IntraServer,fc@1
...