Network Router User Manual
Setting up the DSLPipe DSU
DSLPipe DSU (SDSL) User’s Guide 2-3
Setting the data transmission rate
To set the DSLPipe DSU data transmission rate, use a pen to move the DIP
switches.Table 2-1 shows the DIP switch settings for each rate. Move the DIP
switch down to turn the switch on. Move a switch up to turn it off.
Configuring the unit as either CPE or COE
If you want the DSLPipe DSU to function as a CPE, leave the fourth DIP switch
in the up (off) position. If you want the unit to function as a COE, move the
fourth DIP switch down.
Note: JP3 and JP4 must be installed for Dip Switch 4 to be functional.
Table 2-1. Data transmission settings
Rate DIP Switch 1 DIP Switch 2 DIP Switch 3
144 Kbps ON ON ON
272 Kbps ON ON OFF
400 Kbps ON OFF ON
528 Kbps ON OFF OFF
784 Kbps OFF ON ON
1168 Kbps OFF ON OFF
1552 Kbps OFF OFF ON
2320 Kbps OFF OFF OFF