Maintenance Object Repair Procedures
Page 10-179BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)
10
2 FAIL For the TN556 or TN2208, received a status of Level 1
Pending Activation-Endpoint Active which indicates a
problem with the BRI endpoint or ASAI or AT&T adjunct,
the wiring to the endpoint or adjunct, or the ISDN-BRI
port.
For the TN2198, received a status of Level 1 Pending
Activation. U interface up S/T interface down, which
indicates a problem with the NT1 or the wiring between
the NT1 and the BRI endpoint (S/T interface).
1. As necessary, check and repair the wiring between
the circuit pack and the endpoint or adjunct.
Execute the test port PCSSpp command, and
review the results of the Level 1 Status Inquiry test to
verify the repair. If this test is still failing, proceed to
Step 2.
2. For BRI endpoints, try replacing the BRI endpoint(s)
connected to the port. For ASAI or AT&T adjuncts,
follow the recommended repair procedures of the
manufacturer for link communication problems. For
the NT1, follow the recommended repair procedures
of the manufacturer. Then execute the test port
PCSSpp command, and review the results of the
Level 1 Status Inquiry test to verify repair. If this test
is still failing, proceed to Step 3.
3. Escalate the problem to the next tier.
Table 10-58. TEST #621 Level 1 Status Inquiry — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page