user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-189BRI-SET, ASAI-ADJ, BRI-DAT
10
Hardware Error Log Entries and Test to Clear
Values
Table 10-63. BRI-SET/ASAI-ADJ Error Log Entries
Error Type
Aux
Data
Associated
Test
Alarm
Level
BRI-PORT
Alarm Level
ABRI-PORT
ATT-PORT
LGATE-PORT
ATTE-PT
On/
Off
Board
Test to Clear
Value
0
1
0 Any Any Any Any test BRI-SET
or ASAI-ADJ
ATT-ADJ
LGATE-AJ
ATTE-AJ
2(a) 2-10
2
None
18 0 busyout
station ext
WARNING MAJOR/
WARNING
2
OFF release
station <ext>
130(b) WRN ON test port
PCSS sh
257(c) Any BRI Layer 3
Query (#629)
WARNING MAJOR/
WARNING
2
OFF test station
ext r 2
test
data-module
ext r 2
351(d) 0 None WARNING OFF busyout and
release station
513(e) 0 None
769(f) 0 None WARNING MAJOR OFF
2561(g) 0 None
2562-
2566(h)
0None
2567(o) 0 None
2568(p) 0 None
2817(i) 0 XID Test
(#628)
WARNING MAJOR/
WARNING
2
OFF test station
ext r 2
test
data-module
ext r 2
Continued on next page