user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Routine Maintenance Procedures
Page 5-33Software Upgrade
5
Reboot the System
1. Set the duplicated control cabinet power supply circuit breaker to ON.
2. The system performs the reset level 4 rebooting process by loading
translations from the translation card. This takes 10 to 15 minutes.
3. Peel the paper backing from the new circuit pack position label
(designation strip) and affix it to the front of the duplicated control cabinet.
4. Install a circuit pack blank into the slot previously occupied by the CPP1.
5. Log in as “craft” at the login: prompt on the management terminal.
6. Enter set time, and press
Enter to set the time and ensure that the system
is booted properly.
7. Enter list configuration software-version, and press
Enter to compare the
version number of the Release 5.4 software program (displayed on the
terminal) with the TN790 version number (written on a label on the TN790’s
faceplate). If the version numbers are not the same, change the version
number on the TN790 label so that they agree.
8. Perform a sanity check on the system running the new software by
executing the following commands in this order:
a. status system 1 (to check out unusual status in the system)
b. list station (to ensure that the translation is read in properly)
c. display alarm (to ensure no alarm is raised in the system)
d. list trunk-group (to ensure the translation is read in properly)
e. list hunt-group (to ensure the translation is read in properly)
This ensures there is no translation corruption and the translations can be
saved with the new software.
NOTE:
If the new load must be returned to the previous software load,
re-install the TN786B/CPP1 circuit packs and reboot with the
previous version’s translation card.
9. Get the DOSS order number of the upgrade, and call the regional CSA to
request an “init” login. Once logged in as “init,” the CSA should assign the
DEFINITY ECS R5 option, which automatically sets the 24-hour password
aging for the upgraded system’s customer logins.
NOTE:
Certain forms have changed for DEFINITY ECS R5. Upgraded
translations may appear on a different form, fields may shift within a
form, and the name assignments to particular fields may change.
10. Notify the switch administrator that any previous login names and
passwords still exist, but that the passwords expire in 24 hours. The new
login names and passwords must conform to the requirements below.