Maintenance Object Repair Procedures
Page 10-360CO-TRK (CO Trunk)
10
FAIL Measured transmission performance was in the
unacceptable range as administered on the trunk group
form. Retrieve a measurement report via the list
testcalls command. Make sure that ATMS thresholds
are set properly on page 4 of the trunk group form.
Besides the facility, test failures can be caused by faulty
test lines or switch paths. If the measurements point to a
facility problem, report the results to the trunk vendor.
8000 FAIL Measured transmission performance was in the
marginal range as administered on the trunk group form.
This generally means that the trunk is usable but has an
undesirable amount of noise or loss. If the user does not
report unacceptable effects, it may not be necessary to
take any action. Retrieve a measurement report via the
list testcalls command. Make sure that ATMS
thresholds are set properly on page 4 of the trunk group
form.
Table 10-99. TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page