Maintenance Object Repair Procedures
Page 10-442DID-DS1 (DS1 DID Trunk)
10
FAIL Test failed due to Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If test continues to fail, escalate the problem.
PASS Trunk translation has been updated successfully. The
current trunk states kept in the DS1 Interface circuit
pack and switch software are consistent. If the trunk is
busied out, the test does not run, but returns PASS. To
verify that the trunk is in-service:
1. Enter status-command to verify that the trunk is
in-service. If the trunk is in-service, no further action
is necessary. If the trunk is out-of-service, continue
to Step 2.
2. Enter release-trunk command to put trunk back into
in-service.
3. Retry the test command.
0NO
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are
correct. Use the list config command, and resolve
any problems that are found.
2. If the board was found to be correctly inserted in
step 1, issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, check to see that
there is a valid board inserted.
Table 10-123. TEST #36 Port Audit and Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page