user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-462DID-TRK (DID Trunk)
10
Port Audit Update Test (#36)
This test sends updates of the DID port translation for all ports on the circuit pack
that have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No
response message is expected from the circuit pack once it receives translation
updates. The port translation data includes: wink or immediate start trunk, dial
tone or rotary dialing trunk, rotary dialing inter-digit timing, Network balance
R/RC, and disconnect timing.
PASS Current flow was detected for this port.
1. User-reported troubles on this port should be
investigated using other port tests and by examining
connections.
2. Refer problem to the CO.
0NO
BOARD
The test could not relate the internal ID to the port (no
board).
1. Check to ensure that the board translations are
correct. Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should
re-establish the linkage between the internal ID and
the port.
Table 10-126. TEST #35 Port Diagnostic Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page