user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-489DIG-LINE (Digital Line)
10
A Conference Test is done next for the primary information channel. This test is
the same as Conference Test #6.
Only one value (Pass, Fail, or Abort) is generated as a result of four tests run. If
any test fails or aborts, the sequence is stopped.
Table 10-132. TEST #13 Voice and Control Channel Local Loop Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call. Use display port
UUCSSpp/PCSSpp to determine the station extension or
attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the
service state indicates that the port is in use, then the port is
unavailable for certain tests. (See Chapter 10, "Maintenance
Commands and Trouble-Clearing Aids", for a full description
of all possible states.) You must wait until the port is idle
before retesting. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, escalate the problem.
Continued on next page