Maintenance Object Repair Procedures
Page 10-595DS1-BD (DS1 Interface Circuit Pack)
10
The
list measurements ds1 summary
command will display the length of time the
test ran (
Test Duration
field) and number of bit errors detected (
Loopback/Span
Test Bit-Error Count
field).
To restore the trunks or ports on the TN767E DS1 Interface circuit pack to the
in-service state, execute the release board command.
Table 10-166. TEST #1216 End Loopback/Span Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the
test ds1-loop PCSS end-loopback/span-test
command at
1-minute intervals a maximum of 5 times.
1005 ABORT End Loopback/Span Test cannot be executed in the current configuration. To
run this, the TN767E or later suffix DS1 must be administered for 24-channel
operation. The "Bit Rate" field on the DS1 circuit pack administration form must
be set to "1.544" for 24-channel operation.
1015 ABORT Ports on the DS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board PCSS command to put all trunks or ports of the
DS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
ABORT Internal system error
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page