user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-622DUPINT (Duplication Interface Circuit Pack)
10
Table 10-179. TEST #315 Duplication Interface Circuit Pack
Status Query Test
Error
Code
Test
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT The software timed out waiting for the reply message.
1. Rerun the test.
2. If the message times out again, then continue to the next step. If the
query fails with a NO BOARD, then refer to NO BOARD on the next
page of this table.
3. No response is being received from the Duplication Interface circuit
pack or Maintenance/Tape Processor. If Duplication Interface circuit
pack A is under-test, then check for and resolve all alarms against the
active PR-MAINT (Maintenance/Tape Processor). If Duplication
Interface circuit pack B is under test, then enter the test dup a system
technician command and resolve problems with Test #315 for
Duplication Interface circuit pack A first.
4. Rerun the test. If it still aborts, then a problem may exist with one of the
serial links. If carrier B is active or Duplication Interface circuit pack B
is under test, then the serial link to get to Duplication Interface circuit
pack B is being carried by the ICC. Check for damage to the ICC, and
verify that all four connectors for the ICC are plugged in. If the ICC has
to be replaced, the system must be powered down.
5. If the ICC is not the problem, then that portion of the serial link wired
into carrier A and/or carrier B may be defective, and the carrier pack
may need to be replaced.
2033 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page