user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-707EXP-LINK (Expansion Interface Link)
10
had to reset the Expansion port network served by the Expansion Link.
Error type 10004 should have been logged against the Expansion
Interface circuit pack that reported the traffic congestion.
e. Aux Data value of 8 means that the link is down due to the recovery
feature of the EPN Sanity Audit. Look for EPN-SNTY errors in the error log,
and refer to the EPN-SNTY section for more details.