user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-731FL-DATA (Flash Data Consistency)
10
128 ABORT The Translation memory card in the Active SPE is missing.
132 FAIL The load vintages are different in both SPEs and the translation
memory card is missing in the Active SPE.
1. Follow the procedures for Error Code 4 to correct the software
vintage.
2. Insert the translation memory card in the Active SPE.
3. Run the test card-mem long command again to resolve alarms.
160 FAIL The update file in the Active SPE is more current than the Standby
SPE and the translation memory card is missing in the Active SPE.
1. Have INADS issue the copy update-file command. If the update
file copy passes, proceed to Step 2.
2. Insert the translation memory card in the Active SPE.
3. Reissue the test card-mem long command to resolve the alarms.
164 FAIL The load vintages and the update files are different in both SPEs, and
the translation memory card in the Active SPE is missing. The update
file in the Active SPE is more current.
1. Both load vintages and update files should not be mismatched.
192 FAIL The update file in the Standby SPE is more current and the translation
memory card is missing in the Active SPE.
1. Follow the procedures for Error Code 160.
196 FAIL The load vintages and the update files are different in both SPEs, and
the translation memory card in the Active SPE is missing. The update
file in the Standby SPE is more current.
1. Follow the procedures for Error Code 164.
Table 10-205. TEST #421 Flash Data Consistency Check Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page