Page 10-758HYB-LINE (Hybrid Line)
10
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1,2,3 FAIL No response was received within the allowable time
period on one of the transmissions to the terminal. This
indicates that something is wrong with the data link to
the voice terminal. This could be a sleeping set problem
or it may be due to wiring or an unplugged or defective
set.
1. Check for errors in the error log, for example, error
1537.
2. Remotely issue the busyout and release busy
commands, and run the short test sequence on the
port to check for other errors associated with the port
or terminal.
3. Check the wiring to the set if it appears that the
terminal is not responding to any tests; otherwise,
replace the terminal and rerun the test.
4. If the test still fails, replace the circuit pack and
reconnect the original terminal.
PASS Hybrid Line Remote Digital Loop Around Test passed.
The hybrid circuit pack is sending and receiving proper
messages to and from the voice terminal.
1. If problems still exist, investigate using other circuit
pack tests and by examining the station, wiring, and
connections.
Table 10-211. TEST #59 Hybrid Line Remote Digital
Loop Around Test Continued
Error
Code
Test
Result Description/ Recommendation