Page 10-843ISDN-TRK (DS1 ISDN Trunk)
10
2211 ABORT Internal system error
1. Follow the recommendations for ABORT code 2012.
2212 ABORT Call terminated by unexpected disconnect.
1. Wait 1 minute and then try again.
2213 ABORT The call has timed-out, perhaps because of a lack of system resources.
1. Follow the recommendations for ABORT code 2035.
2214 ABORT Call terminated by unexpected disconnect.
1. Wait 1 minute and then try again.
2215
2216
2217
2218
2219
ABORT Internal system error
1. Follow recommendations for ABORT code 2012.
2220 ABORT Call terminated prematurely.
1. Wait 1 minute and try again.
2221
2222
2223
2224
2225
2226
ABORT Internal system error
1. Follow recommendations for ABORT code 2012.
2227 ABORT Could not allocate the necessary system resources to run this test.
1. Follow the recommendations for ABORT code 2100.
2042 FAIL This is the main purpose of the test. The comparison of the data sent
with the data received indicates a loss of integrity on the communications
path.
1. The trunk should be taken out-of-service and the quality of the DS1 line
should be investigated. The investigation should include an in-depth
analysis of the DS1 facility including the transmission facility and any
external equipment such as DACs, CSUs, etc. If the test isdn-testcall
command is invoked, then the investigation should include getting the
bit and block error rates by invoking the status isdn-testcall
command.
Table 10-237. TEST #258 ISDN TEST CallContinued
Error
Code
Test
Result Description/ Recommendation
Continued on next page