user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-996OPS-LINE (DS1 OPS Line)
10
2000 ABORT The test was aborted because response to the test was
not received within the allowable time period.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test aborts with error code 2000 again, run
short test sequence on the associated DS1-BD or
UDS1-BD. If tests 138 through 145 on the
associated DS1-BD or UDS1-BD are also aborting
with error code 2000, hyperactivity on the board or
facility is indicated. In this case, the hyperactivity
problem should be dealt with first.
3. If the test continues to abort, escalate the problem.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
7 or 8 FAIL Test failed due to internal system error. Do not replace
port board.
Error code 7: the failure occurred during station
translation download (to DS1 Interface circuit pack).
Error code 8: the failure occurred during station
ringer update.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to fail, escalate the problem.
PASS Trunk translation has been updated successfully. The
current trunk states kept in the DS1 Interface circuit
pack and switch software are consistent.
Table 10-287. TEST #36 Audit and Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page