user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-999OPS-LINE (DS1 OPS Line)
10
2000 ABORT The test was aborted because response to the test was
not received within the allowable time period.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test aborts with error code 2000 again, run
short test sequence on the associated DS1-BD or
UDS1-BD. If tests 138 through 145 on the
associated DS1-BD or UDS1-BD are also aborting
with error code 2000, hyperactivity on the board or
facility is indicated. In this case, the hyperactivity
problem should be dealt with first.
3. If the test continues to abort and the board is OK,
escalate the problem.
2012 ABORT The test was aborted due to a system error.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1 FAIL Internal System Error.
1. Look for DS1-BD errors in the Hardware Error Log. If
present, refer to the DS1-BD (DS1 Interface Circuit
Pack) Maintenance documentation.
2. If a channel multiplexer is used as the remote DS1
endpoint to which the station connects, refer to the
multiplexer vendor’s maintenance document for
diagnosis.
3. Retry the command at one-minute intervals a
maximum of five times.
4. If the test continues to fail, escalate the problem.
PASS The station hook states in both switch software and DS1
Interface circuit pack are consistent.
Table 10-288. TEST #312 DS1OPS Switchhook Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page